FEATURES & BENEFITS
- AC waveform of 0.2 – 2.0 MHz
- Square wave electroporation capabilities
- A wide range of voltages from 5 V to 3000 V
- Fine voltage discrimination
- Advanced programming capability to combine multiple AC steps pre- and post-DC fusion step
- Capable of operating at low impedance loads
- Large touchscreen interface
APPLICATIONS
ELECTROFUSION
Fast, efficient cell fusion in hybridoma production, hybrid cell formation and nuclear transfer applications are facilitated by the combination of AC sine wave and DC square wave pulses. Fusion is achieved by the generation of an AC current sine waveform that generates a benign dielectrophoretic alignment of cells. Next, a DC square waveform is applied to promote fusion between aligned cells. After fusion, the AC sine waveform is reapplied maintaining the cell compression for the rounding off process resulting in a higher number of hybrids.
ELECTROPORATION
Electroporation is a standard method used to transfect mammalian cell lines to express recombinant human proteins which are used for therapeutic purposes. Gene delivery by this method is typically used in transient transfections to study protein expression or to temporarily knockout or “silence” these genes using siRNA. This is used to study gene targeting and function.
Square waveform electroporation is an efficient non-viral method for transfecting genes and other molecules into mammalian cell lines. This technology is commonly used to study gene targeting, function and to understand protein regulation.
Alternatively, adding additional selection steps to isolate stably transfected cells allows for ;integration of a gene into the genome of the cell for long term expression of protein. The use of the ECM 2001+ offers the control needed to adjust electrical settings for optimization of parameters. This system is powerful enough to yield high transfection efficiencies for cell lines and difficult to transfect cell types including stem cells and primary cells. The gentle square wave pulse also allows for high cell viability of these cell types.
SPECIFICATIONS:
Square Wave Pulse, DC | |
Voltage Range | |
LV Mode | 5 to 500 V in 1 V steps |
HV Mode | 505 to 3000 V in 1 V steps |
Voltage Accuracy | |
LV Mode | 5% |
HV Mode | 5% |
Pulse Length Range | |
LV Mode | 10 to 999 µs in 1 µs steps |
LV Mode | 1 to 999 ms in 1 ms steps |
HV Mode | 10 to 600 µs in 1 µs steps |
Multiple Pulsing | |
LV Mode | 1 to 10 pulses per sample |
HV Mode | 1 to 10 pulses per sample |
Pulse Interval | 0.1 s to 10 s |
Alignment (Pre-Pulse), AC | |
Frequency | 0.2 to 2 MHz in 0.1 MHz steps |
Voltage | 5 to 75 V in 5 V steps |
Duration | 0 to 99 s in 1 s steps |
Wave Shape | Sine wave |
Post-Fusion, AC | |
Frequency | 0.2 to 2 MHz in 0.1 MHz steps |
Voltage | 5 to 75 V in 5 V steps |
Duration | 0 to 99 s in 1 s steps |
Wave Shape | Sine wave |
Sample Load Ranges | |
AC | |
All Voltages | Load must be ≥60 Ω> |
DC | |
LV Mode | Pulse Length <100 ms, Load must be >8 to 9 Ω, Pulse Length >100 ms, Load must be >100 Ω |
HV Mode | Pulse Length ≤600 ms Load must be ≥40 Ω |
Other Specifications | |
Charging Time | LV = 7 s, HV = 7 s |
DC Monitoring | Protocol Name, Steps Executed, Time/Date, Error Conditions, Pulse Voltage, Pulse Current, Pulse Width, Pulse #, Droop %, Sample Voltage, Sample Current and Sample Resistance |
Display | 7-inch full color display |
Controls | Touch Screen |
Programmability | Stores over 1000 protocols |
DC Arc Control | Yes |
Pre-Pulse Sample Load Check | Ves (20 V DC) |
Computer (Optional) | PC running Microsoft Windows XP, 7, 8.1 or 10 |
Communications | USB |
Data File Format | Comma Separated Values (CSV) |
Remote Operation | Yes, using Foot Pedal control |
Accessory Connector Type | Coaxial |
Power Ratings | 70 W idle and 900 W pulsing |
Input Voltage Ratings | 100 to 240 VAC, 50 / 60 Hz |
Dimensions (H x W x D) | 13 x 12 x 13 in |
Weight | 22 lb |
Warranty | 2 years |
Atmospheric Specifications | |
Operating Temperature | 4°C to 40°C (40°F to 104°F) |
Storage Temperature | -10°C to 70°C (14°F to 158°F) |
Operating Humidity | 20% to 80% RH, non-condensing |
Storage Humidity | 20% to 80% RH, non-condensing |
Mode of Operation | Continuous |
Classification | Class I |
Pollution | IP2X |
Installation | Category II |
Regulatory Certifications | CE, ETL (UL, CSA), FCC, WEEE, EU RoHS & CB Scheme |